Tornado(ES)

  • Model :Tornado(ES)
  • Sweep : 450mm
  • R.P.M :1400
  • Input Power Max (w): 300
  • Air Delivery(M3/Hr):6120

Description

  • Comfort range of exhaust fans have been totally redesigned as per market conditions and a better and stronger version has been introduced and renamed as comfort MK II
    Ideal for exhausting stuffy fumes from work rooms, bakeries, kitchen, bathrooms, workshop & chemical plants etc. Extensively being used for desert coolers.

 

  • Salient Features
    • 100% Water resistant Motor (IP:55 Protection).
    • 100% Dust Proof.
    • Can Withstand Wide Voltage Fluctuations (170v-270v).
    • Dynamically Balanced Blades for Vibration free running.
    • Rust Proof Due To epoxy powder coating.
    • Extra powerful Motor, totally enclosed with double ball bearings lubricated for life.
    • Powder coating after 11 tank pre-treatment.

 

  • Construction Details
    • Pressure die cast aluminium parts.
    • Carbon steel shaft for higher strength.
    • Double sealed ball bearings, lubricated for life.
    • All rotating parts dynamically balanced for long bearing life.

     

Can Withstand Wide Voltage Fluctuation (170v-270v)

SWEEP R.P.M. MODEL INPUT POWER (W) AIR DELIVERY (M3/HR.)
230 MM 2800 COMFORT MK II NEO 100 2200
300 MM 1400 COMFORT MK II 90 1710
380 MM 1400 COMFORT MK II 180 3250
450 MM 900 COMFORT MK II
REGULAR
SHAKTI
145 3900
450 MM 1400 REGULAR
SHAKTI
TIGER
RAKSHAK
325 6120
230 MM 2800 COMFORT MK II 240 4500
425 MM 1400 COMFORT MK II 350 6120
 450 MM 1400 TORNADO (ES) 300 6120
 450 MM 1400 SPEED (ES) 210 4520
600 MM 900 REGULAR 500 9400
* 600 MM 1400 MAHABALI 1100 18000
600 MM 1400 MAHABALI – 2X 1550 30000
NEW ARRIVALS
230 MM 2800 SUPER SILENT 100 2200
300 MM 2400 SUPER SILENT 310 4800
600 MM 1400 M.S.S 620 15500
700 MM 1400 THUNDER 1500 40000

For the first time in India high performance powerful fan for factories, guesthouses,
workshops, halls, open spaces etc.

SELECTING THE RIGHT EXHAUST FAN FOR YOUR NEEDS

  • Ventilation essentially means replacing stale, hot air with fresh air and the size and number of exhaust fans required for a particular application is directly dependent upon location and the number of air changes required per hour. Thus, to determine correct size and number of fans, the following factors need consideration:Size of room.
  • Number of occupants and their activities.
  • Heat gain from solar radiation, machinery, etc.
  • Relative humidity and outside air temperature.

RECOMMENDED AIR CHANGES

There are no rigid rules and recommendations regarding the number of air changes required for adequate ventilation; every building has it own characteristics and much depends on prevailing conditions.

HOW TO ESTIMATE REQUIRED VENTILATION

To estimate the ventilation required for a given area calculate the total interior space in cubic meters (length x width x height) multiply the figure you get by the particular number of air changes from the table above. Check this figure with the air delivery of the particular size of the fans & select the size and the number of fans needed.